4 District Regulations

4.1000 Light Industrial ("I") District

  1. Purpose and Intent
    The purpose of the Light Industrial (“I”) District is to provide for a limited range of low-intensity industrial uses, provided the uses are not noxious or offensive due to odors, smoke, dust, noise, fumes or vibrations. This district is intended to serve the entire community.
  2. Uses
    In the Light Industrial (“I”) District, no building or land shall be used and no building shall be hereafter erected, reconstructed, altered or enlarged, nor shall a Certificate of Occupancy be issued, except in accordance with the use tables in Chapter 4, Articles 6 and 8 and the supplemental use standards of Chapter 5.
  3. Property Development Standards
    The minimum dimension of lots and yards and the height of buildings in the Light Industrial (“I”) District, shall be as shown in the accompanying table.

Light Industrial (“I”) District

Front Yard*

None required if entire block frontage is zoned “FR” through “K”; if the block frontage contains a residential district or the “ER” or “E” District, the most restrictive district standards apply.

Rear Yard*

10 feet minimum adjacent to residentially zoned lot, none otherwise

Side Yard*


Interior lot 5 feet minimum adjacent to residentially zoned lot, none otherwise.  If provided, side yard must be 3 feet minimum
Corner lot** None required unless through lot, then 10 feet minimum required

Height

3 stories or 45 feet maximum, provided, however, Stealth Telecommunication Towers are permitted to a height of 75 feet.  The Urban Design Commission must approve the design of all Stealth Telecommunication Towers.  Telecommunication Towers are permitted to a height of 75 feet.

Notes:

* Additional setback may be required by Sections6.101C or 6.300.

**May be subject to projected front yard (Section 6.101F).

D. Other Development Standards

Development in the Light Industrial (“I”) District may be subject to a variety of general development standards, including, but not limited to:

1. Off-Street Parking and Loading. Industrial buildings require one space per 500 square feet of gross floor area or one space per three employees, whichever is greater. Warehouse buildings require one space per four employees, with a four-space minimum.  For further details, other uses, and loading areas, see Development Standards, Article 2.

2. Landscaping and Buffers. For industrial uses, generally, four percent of net site area, or a landscape area of 30-foot depth along all public rights-of-way.  See Development Standards, Article 3. 

3. Signs. See Development Standards, Article 4. 

4. Maximum Horsepower. No use in the “I” District shall employ machines that exceed 50 horsepower. Line Compressors shall be exempt from this limitation. (Ord. 18504, eff. 3/12/09)